Technical Specification Information - Firefold Partitions |
Fire Performance |
Panel weight Kg/m² |
Series Ref./NBS Specification |
Max height mm |
Nominal panel thickness |
Configuration |
Half-Hour fire rating
Flame spread rating class 1
Flame spread rating class 0*
|
28 (veneer 30 (laminate) |
FF54
|
3000 |
54mm |
Top Hung with Floor Guide Sidefold or Centrefold |
One-Hourfire rating
Flame spread rating class 1
Flame spread rating class 0*
|
33 veneer 35 (laminate |
FF60
|
2600 |
60mm |
Top Hung with Floor Guide Sidefold or Centrefold |
* Class 0 requires intumescent lacquer Optional brush stripping and neoprene seals to enhance acoustic rating |
|
Specifications:
- Maximum opening width - no limit, use any number of same width floating units
- Panel width 600 - 900mm
- Class '1' Surface Spread of Flame rating
- One-Hour or Half-hour fire rating
Standard construction consist of:
- Solid core timber construction
- Hardwood lipping to vertical edges
- Constructional veneer to both faces
- Galvanised steel track
- Steel wheeled bearing carriers
- Brass floor channel
- Intumescent strip seal on panel to panel rebated joints
- Faces finished as required (Veneer, Laminate etc.)
Options:
- Top and bottom - brush stripping to enhance acoustic rating
- Vertical edges - Neoprene smoke seal to rebated joints
- Independent "floating" units for larger openings
Sidefold |
Centrefold |
|
Normally attached to the jamb post in continuous hinged unit
to a maximum of five panels, projecting to one side of the
opening. For wider openings, independent floating 4 or 6'
panel units can be used. Units can be designed to park at
one or both ends of the track run in single stacks.
Sidefold drawing
|
Normally consisting of an odd number of full-width panels
plus on half-width panel, continuously hinged to the jamb,
a maximum of five and a half panels. For larger openings,
additional 3 or 5 panel "floating" units may be
employed.
Centrefold drawing
|
Firefold Partitions Fire Performance
Firefold partitions offer Class '0' Surface spread of Flame as defined
in paragraph A12(b) of Approved Document B, "Fire Safety, to
the Building Regulations, 1991. Care should be taken that the subsequent
site decoration does not compromise this rating. Where applied finishes
other than standard are specified, advice should be sought from
you local fire officer.
Firefold partitions have been tested to BS476: Part 8: 1972 and
offer half-hour or one-hour fire resistance. The attitude of local
fire authorities to fire resistance and suitability may vary from
one area to another and it is the responsibility of the specifier
to assure himself that the product will be acceptable to those authorities
in the selected location.
Warranty
All Hufcor products are guaranteed for two years against defective
materials and workmanship
top
|
|